INSTALLATION

HT4400

Instruction Manual

3-21

2

Machine Interface Connections - 2 of 2

Cable - Machine I/O Interface to
Power Supply

Installation Notes

If using the Command THC, do not connect this cable.

RUN LIST –

Machine I/O Interface t

Power Supply Cable

SIGNAL

Terminal

COLOR 1X6

Remote OFF**

78

Green

32

Remote ON**

79

Red

37

Remote ON/OFF Shield**

Cut

Shield

26

Hold Signal (12VDC) Signal. Closed-ON;Open=OFF

87

White

1

Hold Common

86

Black

5

Hold Shield

Cut

Shield

10

Plasma Start (12VDC) Signal. Closed=Start

82

Blue

9

Plasma Start Signal

83

Black

15

Plasma Start Shield

Cut

Shield

14

Plasma Emergency Stop (24VAC) Signal. Closed=Stop 80

Yellow

28

Plasma Emergency Stop Signal

81

Red

33

Plasma Emergency Stop Shield

Cut

Shield

27

Arc Xfer Output - Signal. Dry contact relay†*

84

Red

36

Arc Transfer Output - Signal*

85

Blue

31

Arc Transfer Output - Shield*

Cut

Shield

25

Pierce Complete***

135

Orange

4

Pierce Complete***

136

Black

8

Pierce Complete Shield***

Cut

Shield

13

Error Counter

167

Green

35

Error Counter

168

Black

30

Error Counter Shield

Cut

Shield

24

Notes:

* Contact closes after arc transfer and time delay
** To enable a remote ON/OFF switch, the jumper on TB4 must be moved from

terminals 1&2 to terminals 2&3 - see figure.

*** A contact closure will activate pierce complete and keeps shield in preflow

mode. Open the contacts for shield cutflow mode.

Note on the µP PCB that resistor R150 and capacitor C78 are connected in
series across the contacts. In some cases, one lead of R150 must be cut from
the control PC board, as the R-C circuit may provide enough current flow to
maintain machine motion input to the cutting machine.

1X6

Part No.

Length

123574

10 ft (3 m)

123575

15 ft (4.6 m)

123576

20 ft (6.1 m)

023892

25 ft (7.6 m)

123577

30 ft (9.2 m)

123578

40 ft (12.2 m)

023893

50 ft (15.3 m)

Part No.

Length

123579

60 ft (18.3 m)

023894

75 ft (22.9 m)

023895

100 ft (30.5 m)

123089

125 ft (38.1 m)

023896

150 ft (45.8 m)

123033

175 ft (53.4 m)

023897

200 ft (61 m)

(Logic +
12VDC,
close to
start)

**Move jumper to TB4
terminals 2&3 to enable
a remote ON/OFF switch

WARNING

W

hen installing or servicing the HT4400, AC or DC line voltages may be present on the

TRANSFER signals even if the power supply line disconnect switch is OFF. Make certain that
all line disconnect switches relating to the HT4400 system are OFF during installation and when
servicing.