Power supply -4 – Hypertherm HT4400 HySpeed Plasma Arc Cutting System User Manual

Page 29

Advertising
background image

Maximum OCV (U

0

)

361 VDC

Maximum Output Current (I

2

)

400 Amps

Output Voltage (U

2

)

80-200 VDC

Duty Cycle Rating (X)

100% @ 89 kVa, 104° F (40° C)

Temperature Rating

14° F (-10° C) to 104° F (40° C)

Power Factor (cos

ϕ

)

0.94

Cooling

Forced Air (Class F)

Input Power (Input Voltage [U

1

– Input Voltage; I

1

– Input Current])

077036

200 VAC (U

1

), 3 Phase, 50-60 Hz, 257A (I

1

)

077037

400 VAC (U

1

), 3 Phase, 50-60 Hz, 128A (I

1

)

077046

440 VAC (U

1

), 3 Phase, 50-60 Hz, 117A (I

1

)

077033

480 VAC (U

1

), 3 Phase, 60 Hz, 107A (I

1

)

077038

600 VAC (U

1

), 3 Phase, 60 Hz, 86A (I

1

)

*

In accordance with IEC 61000-3-12, the Rsce (short Circuit Ratio) for the 400 VAC power supply is 100.

Dimensions and Weight

Width

34" (863 mm)

Maximum Height

51" (1295 mm)

Maximum Depth

48-11/16" (1236 mm)

Weight

1800 lbs (817 kg)

SPECIFICATIONS

2-4

HT4400

Instruction Manual

3

Power Supply