Aluminum, English, Metric – Hypertherm HT4400 HySpeed Plasma Arc Cutting System User Manual

Page 199: Plasma / o, Shield 200 amps

Advertising
background image

HT4400

Instruction Manual

f-9

2

Aluminum

N

2

Plasma / O

2

-N

2

Shield

200 Amps

Air

120786

Retaining Cap

120794

Nozzle

120853

Swirl Ring

120855

Electrode

*

Piercing not recommended

Minimum inlet pressures remain at one setting of 120 psi (8.3 bar) for all material thicknesses.
Approximate pressures while cutting in RUN mode:

PG1

49

PG2

36

Flow Rates @ 120 psi (8.3 bar)

(scfh / slh)

N

2

O

2

Preflow

199.4 / 5646 54.5 / 1542

Cutflow

191 / 5406

47.7 / 1350

MV1 MV2 MV3 MV4 MV5

MV6 MV7 PG1 PG2 PG1 PG2

Inches

Volts

in.

mm

ipm

mm/m

in.

mm

seconds

3/16

130

.125

3

180

4570

.250

6

0.5

1/4

135

.125

3

160

4060

.250

6

1

3/8

135

.125

3

120

4050

.250

6

1.5

1/2

140

.125

3

80

2030

.250

6

2

5/8

140

.157

4

70

1780

.314

8

2

3/4

150

.250

6

50

1270

.500

12

2.5

7/8

160

.250

6

35

890

.500

12

2.5

1

165

.250

6

25

630

*

*

*

1-1/4

175

.250

6

20

510

*

*

*

English

Test Preflow and Cutflow Adjust (psi)

Test

Preflow

Verify (psi)

Test

Cutflow

Verify (psi)

Initial Pierce

Height

Pierce

Delay

Time

Plasma

Shield

Plasma

Shield

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

44

35

30

40

0

5

8

28

44

37

36

MV1 MV2 MV3 MV4 MV5

MV6 MV7 PG1 PG2 PG1 PG2

mm

Volts

mm

in.

mm/m

ipm

mm

in.

seconds

5

130

3

.125

4355

172

6

.250

0.5

6

135

3

.125

4301

169

6

.250

1

10

135

3

.125

2903

114

6

.250

1.5

12

140

4

.157

2151

85

6

.250

2

15

140

4

.157

1851

73

8

.314

2

20

145

5

.188

1210

48

12

.500

2.5

22

145

6

.250

898

35

12

.500

2.5

25

150

6

.250

645

25

*

*

*

30

160

6

.250

543

21

*

*

*

Metric

Test Preflow and Cutflow Adjust (psi)

Test

Preflow

Verify (psi)

Test

Cutflow

Verify (psi)

Initial Pierce

Height

Pierce

Delay

Time

Plasma

Shield

Plasma

Shield

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

44

35

30

40

0

5

8

28

44

37

36

Advertising