Cooler connections - 2 of 2 -19, Cooler connections – 2 of 2 – Hypertherm HT4400 HySpeed Plasma Arc Cutting System User Manual

Page 53

Advertising
background image

INSTALLATION

HT4400

Instruction Manual

3-19

8

Cooler Connections – 2 of 2

Hoses - Cooler to Ignition Console

Part No.

Length

128499

5 ft (1.5 m)

028652

10 ft (3.1 m)

028440

15 ft (4.6 m)

028653

20 ft (6.1 m)

028441

25 ft (7.6 m)

128495

30 ft (9.2 m)

128496

40 ft (12.2 m)

028442

50 ft (15.3 m)

Part No.

Length

128052

60 ft (18.3 m)

028443

75 ft (22.9 m)

028444

100 ft (30.5 m)

028747

125 ft (38.1 m)

028445

150 ft (45.8 m)

128064

175 ft (53.4 m)

028637

200 ft (61 m)

Note: There are 2 hoses contained in each

hose set part number listed here.

Green

Green

Red

Red

Adding Coolant to the Cooler

1. Install consumables in the torch: see Changing

Consumables in Section 4.

2. Remove cooler filler cap.

3. Add coolant until level is full on the level gauge.

4. Turn the cooler on for 1 minute and add more

coolant, if necessary.

See Post Installation later in this section.

See also Torch Coolant Requirements earlier in this
section.

Filter cap

Level gauge

Caution

Use Hypertherm coolant (028872) to reduce the risk of damage from
freezing and to prevent long-term corrosion.