INSTALLATION

3-14

HT4400

Instruction Manual

Ignition Console Connections – 3 of 3

Cable - Ignition Console to Valve Cluster

Torch Leads

Installation Notes

RUN LIST –

Ignition Console to

Valve Cluster Cable

Note: 2X2 and 4X1 are not labeled on the
cable. Plug one cable end into the 2X2 Ignition
Console receptacle and the other cable end
into the Valve Cluster cable receptacle.

SIGNAL

2X2

COLOR

4X1

SV8

7

White

1

SV8

20

Yellow

2

SV9

8

White

4

SV9

21

Orange

5

SV10

9

White

7

SV10

22

Brown

8

SV11

10

White

10

SV11

23

Black

11

SV12

11

White

13

SV12

24

Red

14

PE (Gnd)

6

White

12

PE (Gnd)

12

Green

3

See also Torch Connections, Mounting
and Alignment
later in this section.

Part No.

Length

123509

6 ft (1.8 m)

123510

10 ft (3 m)

Part No.

Length

123511

15 ft (4.6 m)

Part No.

Length

128462

6 ft (1.8 m)

128463

10 ft (3 m)

128341

15 ft (4.6 m)

2X2

4X1