Changing consumable parts -23, Remove consumables -23 – Hypertherm HT4400 HySpeed Plasma Arc Cutting System User Manual

Page 82

Advertising
background image

OPERATION

HT4400

Instruction Manual

4-23

2

1

2

3

4

Tool Part No.

004663

5

Tool Part No.

027102

Changing Consumable Parts

Remove Consumables

Check the consumable parts daily for wear before cutting. Before removing consumables, bring the torch to the
edge of the cutting table, with the torch lifter raised to its highest point to prevent the consumables from
dropping into the water of the water table.

WARNING

The HT4400 power supply is designed to go into an idle mode if the retaining cap is removed.
However, DO NOT CHANGE CONSUMABLE PARTS WHILE IN THE IDLE MODE! Always
disconnect power to the power supply before inspecting or changing torch consumable parts.

Turn OFF all power to the HT4400 system.

Remove retaining cap

Remove nozzle

Remove electrode

Remove swirlring

Advertising