![background image](/files/789770/content/doc127.png)
MAINTENANCE
HT4400
Instruction Manual
5-37
3
MV1
MV1
Gas Console Valve Select Switch Detail
Valve Select Display
BCD Position
Outputs Activated
Run - Preflow
0
SV2, SV4, SV5, SV7, SV8, SV10, SV12
Run - Cutflow
0
SV1, SV3, SV6, SV9, SV11, SV12
MV1
1
SV1, SV11, SV12
MV2
2
SV2, SV10, SV12
MV3
3
SV3, SV9
MV4
4
SV4, SV8
MV5
5
SV5, SV10, SV12
MV6
6
SV6, SV9
MV7
7
SV7, SV8
Leak Test 1
8
SV1– SV7
Leak Test 2
9
SV8– SV12
Test Preflow
10
SV2, SV4, SV5, SV7, SV8, SV10, SV12
Test Cutflow
11
SV1, SV3, SV6, SV9, SV11, SV12