Gas console valve select switch detail -37, Gas console valve select switch detail – Hypertherm HT4400 HySpeed Plasma Arc Cutting System User Manual

Page 127

Advertising
background image

MAINTENANCE

HT4400

Instruction Manual

5-37

3

MV1

MV1

Gas Console Valve Select Switch Detail

Valve Select Display

BCD Position

Outputs Activated

Run - Preflow

0

SV2, SV4, SV5, SV7, SV8, SV10, SV12

Run - Cutflow

0

SV1, SV3, SV6, SV9, SV11, SV12

MV1

1

SV1, SV11, SV12

MV2

2

SV2, SV10, SV12

MV3

3

SV3, SV9

MV4

4

SV4, SV8

MV5

5

SV5, SV10, SV12

MV6

6

SV6, SV9

MV7

7

SV7, SV8

Leak Test 1

8

SV1– SV7

Leak Test 2

9

SV8– SV12

Test Preflow

10

SV2, SV4, SV5, SV7, SV8, SV10, SV12

Test Cutflow

11

SV1, SV3, SV6, SV9, SV11, SV12