After staining, the stain and characterization firing is conducted in a compatible ceramic furnace (e.g. P300). The following

points should be observed when placing the restoration in the furnace and setting the firing parameters:

– Support inlays, onlays, and partial crowns with a firing pillow and place

them on a honey-comb firing tray.

– Place veneers as well as anterior and posterior crowns on metal pins

and position them on the honey-comb firing tray.

– As an alternative to the firing pillow and to better secure the restoration

on the metal pins (particularly with veneers), a small amount

IPS Object Fix may also be used.

IPS Empress CAD with IPS Empress Universal

B

S

t

T H

V

1

V

2

Stain and Characterization firing

403°C

6'

100°C

790°C

1'

757°F

6'

180°F

1454°F

1'

Firing parameters for the Stain and Characterization firing

(note the temperature control)

Place the objects on the honey-comb firing tray and start

the firing program

Optional

Shade check

To check the tooth shade after the first stain and characterization firing,

proceed as follows:

– Wet inner aspects of the restoration with IPS Contour Glaze and Stain

Liquid using a brush.

– Place the restoration on the individual control die and check the tooth

shade, as well as the individualized effects.

– If adjustments are required, apply the corresponding stains and fire

them using the above firing program.

Shade check. If necessary, the shade intensity can be increased

by additional staining.

B = Stand-by temperature °C / °F
S = Closing time/minutes
t

= Temperature increase rate °C/min. / °F/min.

T = Firing temperature °C / °F
H = Holding time / min.

V

1

= Vacuum-on temperature °C / °F

V

2

= Vacuum-off temperature °C / °F