32

In order to individualize restorations in the incisal area so that they correspond with their natural model, the IPS Empress

CAD restoration is additionally veneered using opalescent IPS Empress Esthetic Veneer ceramic materials. The cut-back

technique is very efficient if the fully anatomical anterior crown or the veneer are first designed according to the definite

final shape. After that, the incisal third is reduced and subsequently provided with an individualized aesthetic veneer.

IPS Empress CAD Veneers / Anterior Crowns – Cut-back and layered

Please refer to the corresponding Operating Instructions and/or Manuals of the respective CAD/CAM system

for further information on the CAD/CAM processing procedure. The instructions by the manufacturer must be

observed.

Fully anatomical, milled veneer and anterior crown, which are reduced in the incisal area.

0.5 mm

0.5 mm

0.5 mm

approx.

0.5–1.0 mm

Veneer

Minimum thickness
of the milled objects
after the
corresponding
reduction
= 0.5 mm

Layer thickness =

Limited layering area:
labial, incisal third

0.5 mm

approx.

0.5–1.0 mm

Minimum thickness
of the milled objects
after the
corresponding
reduction
= 0.5 mm

Layer thickness =

Limited layering area:
labial, incisal third