Switch S3 (Figure 2-2) is used to set the configuration parameters listed in the
following paragraphs. Refer to the Terminal Operation chapter of this manual for
more information on the related software-controlled configuration commands.

Network LBO

Positions S3 -1 and S3-2 set the line build out signal level of the transmit data
(TXD) from the unit to the network. The output level is factory set at 0 dB. It may
be attenuated by -7.5 dB, -15 dB, or -22.5 dB if operating conditions require that
it be changed. The telco should provide the proper setting to the user.

If unsure of

the exact setting, then leave it at the default value. The values are listed in
Table 2-1.

DTE LBO

Positions S3-3, S3-4, and S3-5 set the line build out to one of the values listed in
Table 2-2. The transmit output level is selectable according to the cable length
between the DTE port and the attached equipment. The factory default setting is
0-110 feet.

Table 2-1 Network LBO

S3-1

S3-2

Network LBO

Dn

Dn

0 dB

Dn

Up

-7.5 dB

Up

Dn

-15.0 dB

Up

Up

-22.5 dB

Table 2-2 DTE LBO

S3-3

S3-4

S3 -5

DTE LBO

Dn

Dn

Dn

0 -110 ft

Dn

Dn

Up

110-220 ft

Dn

Up

Dn

220-330 ft

Dn

Up

Up

330-440 ft

Up

Dn

Dn

440-550 ft

Up

Dn

Up

550-655 ft

Up

Up

Dn

> 655 ft

Up

Up

Up

Square

7

6

5

4

3

2

1

8

Dn

Up

NE

T

L

B

O

NE

T

L

B

O

DT

E

L

ev

el

DT

E

L

ev

el

DT

E

L

ev

el

C

loc

k

So

ur

ce

C

loc

k

So

ur

ce

C

loc

k

So

ur

ce

Figure 2-2 Switch S3

Advertising