Alarms screen -7, Element -7 net /dte alarms -7 alarm status -7, Alarms screen – Verilink 2000 (34-00182) Product Manual User Manual

Page 41

Advertising
background image

Alarms Screen

4-7

Alarms
Screen

The Alarms screen (Figure 4-5) is used to view the current alarm status of the
network and DTE lines. The fields are described as follows.

Element

The NEAR unit or FAR unit selection is toggled by pressing the spacebar.

NET /DTE

Alarms

These status lines display the selected element’s current network/DTE signal alarm
state. Alarms are determined by the following user-selectable thresholds.

alarm status

The main body of the Alarms screen displays the current count for parameters that
may be used to trigger an alarm.

The Current column shows the total of the preceding 15 one- minute intervals. At
the end of each one -minute interval, the oldest minute of the 15 -minute interval is
discarded.

The Threshold column shows the values set in the Alarm Configuration screen (see
Alarm Configuration on page 4 -18). Any parameter that has a current value equal

2000 CSU x.xx/x.xx

2000 CSU Date

MM/DD/YY

2000 CSU x.xx/x.xx

(Unit Address: xxx)

Time HH:MM:SS

----------------------------------- ALARMS

-------------------------------------

Element: [NEAR]

NET Alarms: NONE
DTE Alarms: NONE

Current

Threshold

Loss Of Signal Seconds (LOSS):

0

5

Errored Seconds (ES):

2

45

Severely Errored Seconds (SES):

2

5

Unavailable Seconds (UAS):

0

0

Out Of Frame Seconds (OOFS):

0

0

Remote Alarm Seconds (RAS):

0

0

AIS Seconds (AISS):

0

0

BPV Seconds (BPVS):

0

0

DTE LOS/OOF Seconds (LOSS/OOFS):

0

5

Power Loss Seconds (PLS):

0

Reset Alarm Registers:

(RESET)

Figure 4-5 Alarms Screen

Table 4-2 Alarm Indications

Alarm

Description

-------

No status is available.

None

No alarm threshold has been exceeded, although
errors may exist which do not exceed thresholds.

ERRS

Errored Seconds, Severely Errored Seconds, or
Bipolar Errored Seconds threshold is exceeded.

LOSS

Loss Of Signal Seconds threshold is exceeded.

OOFS

Out Of Frame Seconds threshold is exceeded.

RAIS

Remote Alarm Seconds threshold is exceeded.

AISS

Alarm Indication Seconds threshold is exceeded.

UAS

Unavailable Seconds threshold is exceeded.

Advertising