Supervisory port bit rate -7 nms bit rate -7, Configuration switch s5 -7, Network line framing -7 – Verilink 2000 (34-00182) Product Manual User Manual
Page 19

Unit Configuration
2-7
Supervisory Port Bit Rate
Positions S4 -5 and S4-6 are used to set the supervisory port bit rate. This is a
serial RS-232 DCE port configured for 8 bits, no parity, and 1 stop bit. Table 2-5
shows the available speeds.
NMS Bit Rate
Positions S4 -7 and S4-8 are used to set the NMS port bit rate. This is a serial
RS-232 DCE port configured for 8 bits, no parity, and 1 stop bit. Table 2-6 shows
the available speeds.
Configuration
Switch S5
Switch S5 (Figure 2-4) is used to set the configuration parameters listed in the
following paragraphs.
Network Line Framing
Position S5-1 is used to match the CSU to the framing of the network line.
Down: ESF Up: D4
Table 2-5 SUPV Port Bit Rate
S4-5
S4-6
SUPV Port Bit Rate
Dn
Dn
19200 bps
Dn
Up
9600 bps
Up
Dn
2400 bps
Up
Up
1200 bps
Table 2-6 NMS Port Bit Rate
S4-7
S4-8
NMS Port Bit Rate
Dn
Dn
19200 bps
Dn
Up
9600 bps
Up
Dn
2400 bps
Up
Up
1200 bps
7
6
5
4
3
2
1
8
Dn
Up
Netw
o
rk
D4
DTE
D4
Netw
o
rk
DTE
AIS
Ke
e
p
A
liv
e
CRC
FD
L
B8
ZS
B8
ZS
Fr
a
m
ed
Lo
op
ed
Pa
ss
Pa
ss
FD
L
T
e
rmin
ate
Ne
tw
ork
ES
F
CRC
K
eep
Al
iv
e
AIS
DT
E
Ne
tw
ork
DT
E
ES
F
AM
I
AM
I
Un
fra
med
AIS
Re
g
en
erate
Figure 2-4 Switch S5