Utilities screen -19, Utilities screen – Verilink 2000 (34-00182) Product Manual User Manual

Page 53

Advertising
background image

Utilities Screen

4-19

Unavailable Seconds

A one-second period in which consecutive severely errored seconds cause an
unavailable state.

DTE LOS/LOF Seconds

A one-second period in which the T1 received signal (on the CSU’s DTE side) is
interrupted or the amplitude drops below a certain level.

Remote Alarm Seconds

Generated by the terminal equipment when an improper signal is received from the
facility (or upon receipt of unframed all ones).

AIS Seconds

A one-second period in which all ones are received.

Out of Frame Seconds

A one-second period in which a frame sync loss occurred.

BPV Seconds

A one-second period in which at least one bipolar violation occurred.

Alarm Reset Timer

Determines the number of seconds after alarm conditions clear before indications
are removed.

Go to Line Settings

Pressing Enter here brings up the Line Configuration screen.

Utilities
Screen

The Utilities screen (Figure 4-16) handles the functions described in the following
paragraphs.

2000 CSU x.xx/x.xx

2000 CSU Date

MM/DD/YY

2000 CSU x.xx/x.xx

(Unit Address: xxx)

Time HH:MM:SS

---------------------------------- UTILITIES

-----------------------------------

Element: [NEAR]

Set Time:

(14:10:13)

Set Date:

(05/12/93)

Alarm Notification:

[DIAL ]

Primary Phone#:

(1 (205) 555-1212 )

Secondary Phone#:

(9,,532-8853,,253 )

Element ID:

(Example CSU 2000 )

New Password:

()

(MAINTENANCE RESET)

Figure 4-16 Utilities Screen