Verilink DCSU 2911 (880-502647-001) Product Manual User Manual

Page 17

Advertising
background image

DCSU 2911 Quick Set-Up

Verilink DCSU 2911 User Manual

2-3

3. From the DCSU Main Menu, select the following:

ACE Controller Menu>
O) ACE Controller Administration Menu>
B) Change ACP Bus

4. Once the bus assignment has been made, reboot the

reassigned module by either

• Using the

Reset

Reset

Reset

Reset command from the ACE Controller

Administration Menu, option R, or

• Reseating the module in its slot.

5. Reconnect to the NCM Local port.

6. Log in. You should now see both modules on the Node Map.

From the NCM Main Menu, select the DCSU application module
using option S, Shelf/Slot. The Main Menu (

Figure 2-2

) uses

brackets to enclose the U, indicating the DCSU.

Figure 2-2 NCM Main Menu

-- VERILINK NCM CONTROLLER : FW Rev 4.15, Dec 13 1997 12:53:30 --

Site Name: Verilink Test Access Level: 2

Managing at NEAR end node [127.255.255.0] Node ID: 0

<- SLOT ->

SHELF 1 2 3 4 5 6 7 8 9 10 11 12 13

0 - - - - - - - - - - - - -

1 D *N [U]

2 - - - - - - - - - - - - -

3 - - - - - - - - - - - - -

4 - - - - - - - - - - - - -

KEY: A=DIDCSU, B=DIU/DBU, C=CSU, D=DIU, E=SDIU, F=DIU/DDS, G=DHDM,

H=ATM/IMUX, I=IDCSU, J=PEP, K=DAC, L=HLM, M=IMUX, N=NCM,

Q=QUAD, R=SUBRATE, S=HSM, T=HDM, U=DCSU, V=VCU, X=QPRI

S) shelf/slot O) administration

C) configuration D) diagnostics

P) performance/status A) alarm

B) circuit manager I) manufacturing info

X) exit this screen

A [127.255.255.0] [1,2] DCSU 2911 >

Menu Heading Area

Node “Map” (Physical

Location of Modules)

Command List

Firmware Version and Date of Release

Access Level (1-4)

Node Address

Node Address

Data (Command) Entry Area

Module Key

Active NCM Master Designator


Asterisk indicates that the NCM is the Main Controller in the shelf

Indicator for the type of shelf: M= Multi-line, D = Dual-line

Brackets around module letter ( [U] ) indicate current module selected