Diagnostics menu, Diagnostics menu -12 – Verilink DCSU 2911 (880-502647-001) Product Manual User Manual

Page 34

Advertising
background image

DCSU T1 Craft Interface

3-12

Verilink DCSU 2911 User Manual

Figure 3-6

DCSU 2911 Configuration Menu (Timing Options)

The following additional timing parameters can be chosen when
the “Receive clock from shelf” option has been chosen (the other
available options are discussed in the previous table):

Table 3-7

Timing Parameters

Diagnostics Menu

Display the Diagnostics Menu using command D from the Main
Menu (Figure 2-1).

Figure 3-7 DCSU 2911 Diagnostic Menu

-- DCSU 2911 CONFIGURATION MENU (TIMING OPTIONS)--

Current shelf timing source: Card 1, INTERNAL (PRIMARY)

Source Slot Number Synchronization Auto Restore

PRIMARY PC) 1 PS) INTERNAL PA) NO

SECONDARY SC) 1 SS) INTERNAL SA) NO

TERTIARY TC) 1 TS) INTERNAL TA) NO

R) Receive clock from shelf: YES

X) exit this screen

[1,1] DCSU 2911 >

Command

Description

Options

PC

Slot number of the card to use as a primary timing source.

MLS: 1—13

QLS: 1—5

DLS: 1—2

SC

Slot number of the card to use as a secondary timing source.

MLS: 1—13

QLS: 1—5

DLS: 1—2

TC

Slot number of the card to use as a tertiary timing source.

MLS: 1—13

QLS: 1—5

DLS: 1—2

-- DCSU 2911 DIAGNOSTICS MENU --

PORT 1 PORT 2 PORT 3 PORT 4

Loop type NONE NONE NONE NONE

Test Pattern NONE NONE NONE NONE

Test Error Counter 0 0 0 0

Ln) Line Loop Pn) Payload Loop

Rn) Local Loop Tn) Test Pattern

An) Send LLB BOP Bn) Send PLB BOP

En) Reset Test Counter X) exit this screen

[1,1] DCSU 2911 >