background image

Troubleshooting

Verilink DCSU 2911 User Manual

5-7

Data Port LEDs

Data Port LEDs display alarm conditions detected at the data ports.
Data Port LEDs 1 and 2 display the status for their respective ports.

Table 5-3

Data Port LED Indicators

System LED

The System LED displays node controller assignments and node
communication conditions.

Table 5-4

System LED Indicators

State

Color

Alarm Class

Possible Error Condition

Solid

Green

All okay

None. (DTE connected and in sync)

Solid

Red

Major

Port active; Signal designated for LOS is not detected. For

example, if you have enabled DTR monitoring (to detect a Loss

of Signal) and you disconnect the cable, a major alarm is

declared.

Solid

Amber

Diagnostic

mode

Port is active and in loopback.

Off

None

None

Port is not enabled.

State

Color

Alarm Class

Possible Error Condition

Solid

Green

None

Module is okay and another module is the shelf controller.

Solid

Red

Critical

System failure. You may need to reseat the card in the shelf.

Off

None

None

Module is not on; no power.

Flashing

Green

None

The module is acting as the controller (that is, it is the shelf

master controlling the ACP bus usage in the shelf).