Verilink DCSU 2911 (880-502647-001) Product Manual User Manual

Page 54

Advertising
background image

DCSU 2911 E1 Craft Interface

4-8

Verilink DCSU 2911 User Manual

Table 4-5

Dual CSU 2911

Timing Parameters

Command

Description

Options

PS

Primary Synchronization: Choose one of the following as the primary

source for clock synchronization.

Net 1: Network port 1

Net 2: Network port 2

External: External clock

Internal: Internal clock

Net 3: Equipment port 1 TT signal

Net 4: Equipment port 2 TT signal

1) NET 1

2) NET 2

3) EXTERNAL

4) INTERNAL

5) NET 3

6) NET 4

SS

Secondary Synchronization: Use this option to specify an alternate source

of timing for synchronization. If the primary source is unavailable, this

source will be used.

Net 1: Network port 1

Net 2: Network port 2

External: External clock

Internal: Internal clock

Net 3: Equipment port 1 TT signal

Net 4: Equipment port 2 TT signal

1) NET 1

2) NET 2

3) EXTERNAL

4) INTERNAL

5) NET 3

6) NET 4

TS

Tertiary Synchronization: Use this option to specify an alternate source of

timing for synchronization. If the primary and secondary sources are

unavailable, this source will be used.

Net 1: Network port 1

Net 2: Network port 2

External: External clock

Internal: Internal clock

Net 3: Equipment port 1 TT signal

Net 4: Equipment port 2 TT signal

1) NET 1

2) NET 2

3) EXTERNAL

4) INTERNAL

5) NET 3

6) NET 4

PA

Primary Auto Restore: Choose Yes to resynchronize to the clock

preference automatically if the clock in the node fails. Otherwise, choose

No to synchronize to other sources (secondary, tertiary) or stay down. In

case of a failure, setting up auto restore helps restore timing. If you have

not set up auto-restore to the primary source because you believe that it

is unstable; but you have chosen a secondary source; after rebooting, the

module will use the latter as the source to restore timing to the module or

shelf.

Yes or No

(Y/N)

SA

Secondary Auto-Restore: Choose Yes to resynchronize to the clock

preference automatically if that clock in the node fails. Otherwise, choose

No to synchronize to other sources (primary, tertiary) or stay down.

Specifying a secondary source for clocking is useful for power failures that

result in the failure of the primary automatic restore source. Restoring

from a secondary source may take up to 60 seconds.

Yes or No

(Y/N)