FBR and BRC components of REMS

4-6

Red Zone Encryption Management System (REMS) User Manual

Figure 4-5

NCC Signal Access Jacks

EQPT IN

The EQPT IN jack breaks the transmission path
toward the DS-1 equipment. This allows an
operator to apply an external test signal to the
equipment receiver.

EQPT OUT

The EQPT OUT jack breaks the transmission
path toward the network and looks toward the
DS-1 equipment transmitter. This jack can be
patched to the test set receiver for signal
measurement.

NET IN

The NET IN jack looks toward the network
when accessed. It can be patched to the test set
transmitter for test signal application to the
network.

NET OUT

The NET OUT jack permits external
measurement of the incoming signal from the
network.

MON

The MON jacks are non-intrusive. When
accessed, each jack permits signal monitoring
by an external test set without interrupting
normal transmission.