FBR and BRC components of REMS
4-6
Red Zone Encryption Management System (REMS) User Manual
Figure 4-5
NCC Signal Access Jacks
EQPT IN
The EQPT IN jack breaks the transmission path
toward the DS-1 equipment. This allows an
operator to apply an external test signal to the
equipment receiver.
EQPT OUT
The EQPT OUT jack breaks the transmission
path toward the network and looks toward the
DS-1 equipment transmitter. This jack can be
patched to the test set receiver for signal
measurement.
NET IN
The NET IN jack looks toward the network
when accessed. It can be patched to the test set
transmitter for test signal application to the
network.
NET OUT
The NET OUT jack permits external
measurement of the incoming signal from the
network.
MON
The MON jacks are non-intrusive. When
accessed, each jack permits signal monitoring
by an external test set without interrupting
normal transmission.