Configuring and starting REMS

6-8

Red Zone Encryption Management System (REMS) User Manual

“Solid Red” events take priority over “Flashing Red” events, except
when a loopback is enabled.

Decoding the NCC 2020 CSU Status (STAT) LED Indicator

The STAT (CSU status) LED is a three-color indicator with six possible
states. This will be the only LED lit when the power-up self test fails.

Solid Green

All OK

Flashing Green

The NCC is being accessed by a thumbwheel
switch operator at the master NCC.

Solid Yellow

An operator test is in progress (that is, a test
signal is currently being applied to the circuit by
the CSU).

Solid Red

Any alarm.

Flashing Yellow and Red

Errors received during user initiated test.

Flashing Red

Power-up self test failure.

Not Lit

No power, blown fuse.

If an alarm state is caused by exceeding the performance monitoring
threshold, the alarm does not clear until the error in the selected intervals
falls below the threshold. This will be equal to one or more 15 minute
intervals.

Decoding the NCC 2020 Network (NET) LED Indicator LED

The NET (network) LED is a tri-state indicator with six states, as follows:

Solid Green

A normal signal is being received from the
network (all OK).

Solid Yellow

NCC is looped toward network via a line
loopback (LLB) or payload loopback (PLB) and
no errors received from the network.

Solid Red

Continuous errors on the network (for example,
LOS, LOF, RAI, AIS).