Iv a, 3 panel functions – DCS 500 User Manual

Page 39

Advertising
background image

Chapter 3 - Handling of Control Panel CDP 31x

DCS 500B / DCP 500B Operating Instructions

IV A

3 - 3

3.3 Panel Functions

The CDP 31x has four different keypad modes:

•

Actual Signal Display Mode (ACT)

•

Parameter Mode (PAR)

•

Function Mode (FUNC)

•

Drive Mode (DRIVE) for further extensions

Actual Signal
Display Mode

ACT

This keypad mode will show, depending on the drive´s history:

•

Actual Signals

•

Faults

•

Fault History Logger

If the ACT-key is pressed immediately after initialization this table is
displayed. If no panel-key is touched for more than one minute the
Actual Signal Display will appear automatically, except when Status
display

or speed reference setting is active. (see chapter 3.13 and

3.15)

0 L 0.0 rpm 00
SPEED AC 0.0 rpm
CONV CUR 0 A
U ARM AC 0 V

Run Status

I = RUN

0 = STOP

Speed

reference

rpm

Main contactor

status
0 = Open

1 = Closed

Control

Location

L = Local

= Remote

ID-number

of the Drive

Statusrow

Actual Signal

Name, value and unit

_

Cursor shows
the selected row

Actual Signal Display

If a fault is effective in the drive, the Fault Display will appear auto-
matically. This will happen with all other modes as well, except the
Drive Mode is active.

Fault Display

0 L 0.0 rpm 00

DCS 500

*** FAULT ***

No ext. FAN ack.

Type of fault or alarm

To select Fault History Display see chapter 3.8

1 = last fault
2 = second last fault
...

Total time after
the power up
HHHH:MM:SS.ss

Fault History Display

0 L 0.0 rpm 00
1 LAST FAULT
I/O-Board not found
0000:14:12.64

Fault or alarm name


3ADW000055R0401_DCS500B_Operating Instruction_e_d

Advertising