DCS 500 User Manual

Page 63

Advertising
background image

Chapter 4 - Signals and Troubleshooting


DCS 500B / DCP 500B Operating Instructions

IV A

4 - 11

Code

seven

segm.

display

Text on

LCD of control panel

CDP 31x

Definition /

Action

Status

signal

(FAULT_WORD_1/2)

Remark

F 65

Reversal Fault

Reversal of direction of current is not O.K.

The reversal of the direction of current was
not correct.
Check: - External cabling between both

thyristor power converters;

- Correct plugging in of flat cable

X18:?

11103

bit 15

(3)

F 66

Current Difference

Current feedback difference (deviation) be-
tween Master and Slave Drive

There is a current feedback difference (de-
viation) between Master and Slave Drive (in
twelve pulse configuration).
Check: - Parameter settings

[P 3606]

and

[P

3605]

;

-

Power-circuit

cabling;

- Symmetry of control logic and

scaling of signals exchanged

between Master and Slave Drive.

11103

bit 14

(3)

3ADW000055R0401_DCS500B_Operating Instruction_e_d