Chapter 3 - Handling of Control Panel CDP 31x

IV A

3 - 12

DCS 500B / DCP 500B Operating Instructions

3.10 Setting of the Display Contrast

Step

Function

Press key

Display after key is

pressed

1.

To enter the Function Mode.

FUNC

0 L 0.0 rpm 00
UPLOAD <= <=
DOWNLOAD => =>
CONTRAST 7

2.

To select a function.

0 L 0.0 rpm 00
UPLOAD <= <=
DOWNLOAD => =>
CONTRAST 7

3.

To enter contrast setting func-
tion.

ENTER

0 L 0.0 rpm 00
CONTRAST [7]

4.

To set the contrast.

(1...7)

0 L 0.0 rpm 00
CONTRAST [4]

5.

To accept the selected value.

ENTER

0 L 0.0 rpm 00
CONTRAST 4


3.11 Full Name of output pins

Step

Function

Press key

Display after key is

pressed

1.

To display the full name of the
three actual signals press key
and hold

ACT

0 L 0.0 rpm 00
SPEED ACT FILT
CONV CURR ACT
U ARM ACT

_

2.

To return to the Actual Signal
Display Mode
release key.

ACT

0 L 0.0 rpm 00
SPEED AC 0.0 rpm
CONV CUR 0 A
U ARM AC 0 V

_


3ADW000055R0401_DCS500B_Operating Instruction_e_d