Func – DCS 500 User Manual

Page 40

Advertising
background image

Chapter 3 - Handling of Control Panel CDP 31x

IV A

3 - 4

DCS 500B / DCP 500B Operating Instructions

Parameter Mode

PAR

The Parameter Mode is used for:
-

change the structure in the firmware

-

show signals and their actual status

-

show and change values of parameters, if they are not

write-protected.

When the Parameter mode is entered parameter 101 appears after
initialization, otherwise the selected parameter is shown.

0 L 0.0 rpm 00

17 RAMP GENERATOR

01 RAMP.[IN]

119.03

Parameter and Signal Display

Statusrow

Group number
and name

Subgroup number
and name
Parameter value or
connection to or
status


All function blocks are characterised by inputs and outputs with
numbers. These inputs and outputs can be subdivided into two
categories:

Pins for designating connections

Parameters for setting values, such as ramp-up / ramp-

down time, controller´s gain, reference values, etc.


If a write-protected pin or parameter is selected, the following warn-
ing will be displayed.

**WARNING**
WRITE ACCESS DENIED
PARAMETER SETTING
NOT POSSIBLE



Function Mode

FUNC

The Function mode is used for special functions, such as:

Parameter UPLOAD from drive to CDP 31x

Parameter DOWNLOAD from CDP 31x to drive

CDP 31x display contrast setting

0 L 0.0 rpm 00
UPLOAD <=<=
DOWNLOAD =>=>
CONTRAST 7

Statusrow

Selectable
Functions

Display contrast
adjusting

_

Function Display


3ADW000055R0401_DCS500B_Operating Instruction_e_d