Chapter 4 - Signals and Troubleshooting


DCS 500B / DCP 500B Operating Instructions

IV A

4 - 15

Code

seven

segm.

display

Text on

LCD of control panel

CDP 31x

Definition /

Possible source

Signal

number

(ALARM_WORD_1/2)

Remark

A 134 Backup not allowed

Alarm Change of Parameter Set not allowed

Signal will appear when an attempt has
been made to change from Motor Set 1 to
Motor Set 2 or vice versa, e.g. while the mo-
tor shaft is turning or the line contactor is
switched on.

11105

bit 4

A 136 Write backup alarm

Alarm Write Backup of Values in Non-Volatile
Memory failed

The attempt to save values in non-volatile
memory has failed;
parameter memory could not be erased.

Check: - Is Jumper

S3

enabling the save

routine?

11105

bit 5

A 137 Arm. current ripple

Armature current ripple

One or several thyristors carry no current.
Check: - Current feedback with oscilloscope

(6 pulses within one cycle visible?)

- Branch fuses, thyristor gate con-

nection; gate-cathode resistance.

- Sensitivity of monitoring function:

set

CUR_RIPPLE_LIM

[421] (de

pending on the methode; see F34)

11105

bit 9

Can

not be re-

set

A 138 Init values read

Alarm Initializiation Values read

Default values have been loaded, using
Parameter

[P 11202]

, Value 3 (FACTORY_

SET_VALUE); signal may only be entered in
the Fault Logger.

A 140 Auto-reclosing

Auto-Reclosing (Self-Restart)

This alarm indicates when self-restart is per-
formed. During that time the alarms F29,
F31, F39 and F41 are suppressed. This
function is started when the line voltage
drops below the alarm or error threshold,
when not in synchronism, no field or no line
contactor acknowledgement and with
PWR_LOSS_MODE [9.19] = enable and
PWR_DOWN_TIME [5.10] greater than
zero.

11105

bit 8

modified

in

S21.232

3ADW000055R0401_DCS500B_Operating Instruction_e_d