Watson-Marlow Qdos30 User Manual

Page 35

Advertising
background image

Watson-Marlow qdos30 PROFIBUS Pump User Manual

35

If a leak is detected the leak detect screen (16.1 Leak detection on page 54) will

not be displayed. Bit 10 of the status word will be activated to indicate that a leak

has occurred and the pump will continue to run until the Master indicates what action

should be taken.

Cyclic Data Read (from pump to Master)

16 bit

Byte 1, 2

Status Word

16 bit

Byte 3, 4

Pumphead Measured Speed (unsigned)

16 bit

Byte 5, 6

Hours Run

32 bit

Byte 7, 8, 9, 10

Tacho Counter

16 bit

Byte 11, 12

Read Flow Calibration in μl per revolution

32 bit

Byte 13, 14, 15, 16 Fluid Level

32 bit

Byte 17, 18, 19, 20 Unassigned

32 bit

Byte 21, 22, 23, 24 Unassigned

32 bit

Byte 25, 26, 27, 28 Unassigned

Status Word
Bit

Description

0

Motor running (1= Running)

1

Global Error Flag (1= Error)

2

Fieldbus Control (1= Enabled)

3

Reserved

4

Over current error

5

Under voltage error

6

Over voltage error

7

Over temperature error

8

Motor stalled

9

Tacho fault

10

Leak detected

11

Low Setpoint- Out of range

12

High Setpoint- Out of range

13

Fluid level alert

14

Reserved

15

Reserved

Pumphead Measured Speed

The pumphead measured speed is a 16-bit unsigned integer value that represents

the speed of the pump head in 1/10th of RPM. For example 1205 represents 120.5

RPM.

Hours Run

The hours run parameter is a 16 bit unsigned integer and will represent whole hours

of runtime.

Tacho Counter

The tacho counter is a 32-bit integer value. If the tacho reset bit of the control word

is set, the tacho counter will reset to zero.

Read Flow Calibration

The value is a 16 bit unsigned integer representing μl per revolution.

Advertising