Fitting a new pumphead

Fitting a new pumphead is a reverse procedure of the pumphead removal.

• Remove the new pumphead from its packaging.

• Align the new pumphead with the pump drive shaft and slide into position on the

pump housing.

• Rotate the pumphead in a clockwise direction by approximately 15° to engage

the retaining clamps.

• Tighten the retaining clamps simultaneously to secure the pumphead into position.

• Connect the input and output connections to the pumphead.

• Apply mains power to the pump, press start and run the pumphead for a few

revolutions.

• Stop the pump and isolate it from the mains power supply, then tighten the

clamps further if necessary.