14.14 Fluid recovery mode

In this operating mode the pump can be run in reverse for short periods to recover

fluid/chemicals pumped. This is mainly used for maintenance purposes.

Press the MODE key, using the +/- keys position the selection bar over the fluid

recovery menu option and press SELECT.

If the pump is already running then the following screen will be displayed. The pump

must be stopped before it can be reversed to recover fluid. Press STOP PUMP.

An instruction is now displayed. There is a warning to ensure that your system

design permits reverse flow. If unidirectional valves are installed then reverse flow

will not function and the pump will build up excessive pressure within the pipework.