18 Pumphead replacement

The pumphead is a consumable part and cannot be serviced.

Pumphead

retaining clamps

Left hand

mounted

pumphead

Ensure contaminated pumpheads are not shipped but disposed

of locally according to regulations for contaminated items and

health and safety procedures.

Always isolate the pump from the mains power supply before

changing the pumphead, suction or discharge lines.

It is only possible to fit the pumphead in one orientation with the

arrow pointing upwards.

The pumphead retaining clamps should only be loosened or

tightened by hand.

Note: In this manual we have shown removal and replacement of the left hand

mounted pumphead. Replacing the right hand mounted pumphead is the identical

procedure.

Removing the pumphead

• Drain down.

• Ensure that there is no pressure in the pipeline.

• Isolate the pump from the mains power supply.

• Ensure that protective clothing and eye protection are worn if hazardous products

have been pumped.

• Remove input and output connections from the pumphead.