14.11 Device Related Diagnostic Data

16 bit

Byte 2, 3

Pump Model and Head

16 bit

Byte 3,4

Tubing Size

16 bit

Byte 5,6

Min Speed (unsigned)

16 bit

Byte 7,8

Max Speed (unsigned)

32 bit

Byte 9,10, 11, 12

Software Version Main CPU

32 bit

Byte 13, 14, 15, 16 Software Version HMI CPU

32 bit

Byte 17, 18, 19, 20 Software Version Flash

32 bit

Byte 21, 22, 23, 24 Software version PROFIBUS CPU

14.12 Channel Related Diagnostic Data

Channel related diagnostic blocks are always three bytes long in the following format:

Byte 1

Header

Byte 2

Channel type

Byte 3

Channel Related Error Code

Channel Related Diagnostic Data

Byte 3

Global error

=0xA9 (General error)

Over current

=0xA1 (Short circuit)

Under voltage

=0xA2 (Under voltage)

Over voltage

=0xA3 (Over voltage)

Over temp

=0xA5 (Over temp)

Motor stall

=0xA4 (Overload)

Tacho fault

=0xB1 (Device related 0x11)

Leak detected

=0xB2 (Device related 0x12)

Setpoint out of range- low

=0xA8 (Lower limit exceeded)

Setpoint out of range- high

=0xA7 (Upper limit exceeded)

Fluid level alert

=0xB3 (Device related 0x15)