Watson-Marlow SPS User Manual

Page 11

Advertising
background image

MasoSine SPS sinusoidal pumps User Manual

11

l We recommend renewing the bearings of SPS 200 pumps with cast iron

power frames after running for 10,000 hours at any pressure.

l We recommend renewing the bearings of SPS 200 pumps with stainless steel

power frames after running for the periods shown in the table below.

l We recommend renewing the bearings of SPS 250 pumps with stainless steel

power frames after running for the periods shown in the table below.

Bearings maintenance

200 rpm

400 rpm

600 rpm

800 rpm

1,000 rpm

5 bar

10,000 hours 10,000 hours 6,986 hours

5,239 hours

4,191 hours

10 bar 2,079 hours

1,040 hours

693 hours

520 hours

416 hours

l The bearings of SPS 100 pumps must be renewed after running for the periods

shown in the table below.

200 rpm

400 rpm

600 rpm

1,000 rpm

5 bar

10,000 hours

10,000 hours

10,000 hours

10,000 hours

10 bar

10,000 hours

10,000 hours

10,000 hours

6,260 hours

200 rpm

400 rpm

600 rpm

800 rpm

5 bar

10,000 hours

10,000 hours

10,000 hours

10,000 hours

10 bar

10,000 hours

10,000 hours

10,000 hours

10,000 hours

15 bar

10,000 hours

10,000 hours

10,000 hours

10,000 hours

200 rpm

400 rpm

600 rpm

5 bar

10,000 hours

10,000 hours

10,000 hours

10 bar

10,000 hours

10,000 hours

10,000 hours

15 bar

10,000 hours

7 ,689 hours

5,126 hours

l We recommend renewing the bearings of SPS 400 pumps’ with cast iron

power frames after running for the periods shown in the table below.

200 rpm

400 rpm

600 rpm

5 bar

10,000 hours

10,000 hours

10,000 hours

10 bar

10,000 hours

10,000 hours

10,000 hours

15 bar

10,000 hours

7,210 hours

4,800 hours

200 rpm

400 rpm

600 rpm

5 bar

10,000 hours

10,000 hours

10,000 hours

10 bar

10,000 hours

10,000 hours

10,000 hours

15 bar

10,000 hours

10,000 hours

7,500 hours

l We recommend renewing the bearings of SPS 400 pumps with stainless steel

power frames after running for the periods shown in the table below.

l We recommend renewing the bearings of SPS 500 pumps with stainless steel

power frames after running for the periods shown in the table below.

l We recommend renewing the bearings of SPS 300 pumps with cast iron or

stainless steel power frames after running for 10,000 hours at any pressure.

Advertising