Watson-Marlow SPS User Manual
Page 37
MasoSine SPS sinusoidal pumps User Manual
37
21.2 Adjusting dimension X in models
with stainless steel power frame
Dimension X
Shim ring
Power frame
Bearing housing
Lip seals
Shaft
Bearing housing
retaining screw
Vernier
Dimension X
SPS 100
SPS 200
SPS 250
SPS 300
SPS 400
SPS 500
10.0mm
+0.05
17.5mm
+0.1
17.4mm
+0.1
23.0mm
+0.1
15.0mm
+0.1
25.4mm
+0.1
SPS 200, SPS 250, SPS 300, SPS 400 and SPS 500: adjusting
dimension X
Note: SPS 100 pumps must be returned to MasoSine for dimension X adjustment.
l Remove the front cover, the front support, the front liner, the rotor, the gate
and the gate guide. See 22 Dismantling and assembly.
l Measure dimension X.
l Check this dimension against the table above.
Power frame
Shim ring
Lip seals
Bearing housing
Bearing housing
retaining screw
Dimension X
Shaft
Vernier