33

Error

Cause

Remedy

Pump does
not draw in

Direction of rotation not correct

Check direction of rotation

No wetting liquid in pump

Fill pump with liquid

Screw fastening not tight

Check screw fastening

Suction pipe too long

Adapt suction pipe

Suction pipe too narrow

Adapt suction pipe

Shaft seal leaking

Check all seals for damage

Wearing parts worn

Replace wearing parts

Motor speed not correct

Measure and regulate speed

Gate and gate guide wrongly
positioned

Check position (see 13.2
Changing rotation direction)

Pump does
not deliver

Direction of rotation not correct

Check direction of rotation

Suction and pressure pipe
confused

Check pipe system

Motor speed not correct

Check pump speed against
performance curves—see your
purchase order

Wearing parts worn

Replace wearing parts

Gate and gate guide wrongly
positioned

Check position (see 13.2
Changing rotation direction)

Inserted gate valve closed

Check pipe system

Pump is
noisy

Noises from the drive

Consult manufacturer

Noises from the pump

Consult manufacturer

Suction pipe too small
(cavitation)

Shorten suction pipe or increase
diameter, reduce speed

Knocking noises from the
pumphead

Check for gate valve wear and
replace if necessary

Noises from power frame

Fill oil, change tapered roller
bearings

Coupling not aligned

Align coupling correctly. See 11
Installation.

Pump leaks

Sealing system is leaking

Change seal faces,
static / dynamic or lip seals

O-ring seal leaking

Replace O-ring

Lip seal ring on the power
frame leaking, oil escapes

Dismantle power frame, replace
lip seals

Pump leaks
at front
housing

Housing seal not installed or
wrongly installed

Install housing O-ring correctly
or replace

Housing seal defective

Install housing O-ring correctly
or replace

Pump is
blocked

Foreign body in the pump

Remove foreign body, examine
pump for damage

Power supply interrupted

Check electrical installation and
fuses, check drive

Defect in the drive

Separate the coupling and turn
the pump by hand to confirm

20 Troubleshooting