Pumps with a triple lip seal: removing the pump housing

l Use a 13mm spanner to loosen and remove the two screws (right-

hand thread) and washers which secure the pump housing to the
power frame.

l If necessary, gently tap the pump housing with a soft hammer to free

it. Withdraw the pump housing carefully.

Note: the pump housing is heavy.