Error

Cause

Remedy

Severe wear
after short
operating
time

Solids in the pumped fluid

Change the wearing parts
frequently; check material
compatibility

Pumped fluid is abrasive

Choose larger pump, reduce
speed

Rotor has
wear on one
side

Rotor not tightened correctly
on installation

Tighten shaft nut firmly on
block

Adjusting dimensions changed
after working on the bearing
housing

Check and correct dimension X:
SPS 200 = 17.5 mm +0.1~
SPS 250 = 17.4 mm +0.1
SPS 300 = 23.0 mm +0.1
SPS 400 = 15.0 mm +0.1
SPS 500 = 25.4 mm +0.1
See 21 Adjusting the shaft

Pump not
clean after
CIP cleaning

Cleaning regulation not
complied with. See 17
Cleaning

Choke on the pressure side:
Check that the pressure
difference is 3-4 bar

Rotor has
seized on
liner

Rotor not correctly tightened

Tighten shaft nut firmly on block

Temperature too high
(thermal expansion)

Choose liner with larger
tolerances

Flushing
mate-
rial between
housing and
power frame
leaking

O-ring in the power frame
missing or defective

Install or replace O-ring

Water or
pumped
material in
the bearing
housing

Flushing pressure too high

Flushing must be pressure-
less (attach pressure reducer,
maximum 0.1 bar)

Leakage bores—bore holes
in the power frame where
pumped material can escape if
the seal system leaks—
blocked (see graphic on page
32)

Check leakage bores for free
passage, replace shaft seals on
pump and power frame

Front
Support has
seized on
Rotor

O-ring in the front bearing
missing or worn

Install or replace O-ring

Front bearing wrongly installed

Examine front bearing for
damage and install in correct
position

Product is
leaking from
the bear-
ing housing
openings

Sealing system in the pump is
leaking

Inspect and if necessary
replace the sealing system and
clean the rinsing channels in
the power frame

Pump
assembly
subject to
vibrations

Speed of the drive motor is
too high

Lower the speed of the drive
motor

Smells
and smoke
coming from
the pump

Pump is running dry

Stop the pump immediately.
Check inner parts for damage
and replace if necessary

Corrosion

Corrosion occurs

Eliminate corrosion;
lacquer or use spray oil