MasoSine SPS sinusoidal pumps User Manual

97

l Use a 13mm spanner to remove the bolts, washers and spacers securing the

baseplate. See 13.1 Changing pump orientation.

l Check that the O-rings (arrowed) are in place on the bent outlet. Fit the bent

outlet connection piece and the bent outlet through the bottom hole in the
bearing housing in the same way.

l Refit the baseplate.
l Fill the system with flushing fluid to the level of the top bend of the bent outlet.

Removing the static flushing device

Note: The flushing device (if fitted) must be emptied and removed before
dismantling the pump.
l To remove the static flushing device, pour the flushing fluid from the sight

glass, and reverse the sequence of operations described above.

Note: Nipples may be fitted in place of the static flushing device if desired. Use a
6mm Allen key to tighten them.

l Use a 17mm spanner to tighten it.

The bent outlet connection piece

The bent outlet