Watson-Marlow SPS User Manual

Page 86

Advertising
background image

MasoSine SPS sinusoidal pumps User Manual

86

Pumps with a single mechanical seal: removing the seal and the

static face

l Push the mechanical seal from the rear of the pump housing and remove it.

Note: The mechanical seal is a tight push fit.

l Remove the static face from the mechanical seal.
l You can now access the seal housing O-ring in its groove in the pump housing

(arrowed), and the O-ring in the mechanical seal (arrowed).

The static face

Pump housing O-ring

The mechanical seal

l A graphic making clear how to disassemble and assemble the seal appears in

section 25.1.

Pumps with a single mechanical seal: removing the seal

Pumps with a triple lip seal

See the graphics in section 25.2 and 25.3, and refer to the instructions for the
SPS 200 pump triple lip seal disassembly in section 22.3.1. The SPS 300 and SPS
400 are similar.

SPS 250, SPS

300, SPS

400 and SPS

500 pumps

with a single

mechanical seal

SPS 250, SPS

300, SPS 400

and SPS 500

pumps with a

triple lip seal