MasoSine SPS sinusoidal pumps User Manual

30

l A choke valve should be

installed in the discharge pipe-
line immediately after the
pump. Close the choke valve
slowly until the pressure differ-
ence is correct.

l The CIP time for the pump is

in accordance with the time
required for system cleaning:
usually 20-40 minutes.

discharge

side

suction

side

flow of

cleaning

fluid

choke

valve

X

bar/psi

Y

bar/psi

Y-X ≥

3 bar / 43.5 psi

Steam-in-place (SIP) for MasoSine products

Steam sterilisation kills micro-organisms through the application of moist heat
(saturated steam) under pressure without disassembly.

l Sterilising the pump with standard equipment is possible up to 120°C only at

standstill.

l The pressure should be high enough to ensure that the steam reaches all parts

of the static pump through the existing clearances.

Class II SIP and CIP

procedure

Maximum

temperature

Recommended

pressure differential

CIP

80-90°C / 176-194°F

3 bar

SIP

120°C / 248°F

-

Key CIP and SIP safety information

l A distance of one metre around the pump should be kept clear during SIP to

minimise danger in case of leakage.

l CIP and SIP processes should be monitored continuously.
l If a leak occurs during CIP or SIP, the pumphead should not be touched until

system pressure has been relieved and the pumphead has been allowed to cool
down.

l Ensure that an acclimatisation period is observed after SIP before the pump

process is started. The temperature inside a standard pump should not exceed
85C (176F) during operation.