92

l Hold the rotor vane in the slot of the gate. The rotor is reversible. Use two

hands to position the rotor, the gate and the gate guide together. Push the
assembly into position. The gate and gate guide slide freely into their channel;
the splines within the rotor hub must be aligned with the shaft splines.

l Ensure that the rotor is pushed all the way home.

Fitting the rotor, the gate and the gate guide

The gate and gate

guide

l Check that the two rotor O-rings (visible one arrowed) are in position on both

sides of the rotor.

l Position the gate within the gate guide and hold as one unit.

Check that the gate and gate guide are correctly oriented for the
desired sense of rotor rotation. This is critical for proper operation

The gate and

gate guide oriented for

clockwise rotor rotation

The gate and gate guide orient-

ed for counter- clockwise rotor

rotation

Pressure

side

Suction

side

Suction
side

Pressure
side

SPS 250, SPS

300, SPS 400

and SPS 500

pumps