19 oil change – Watson-Marlow SPS User Manual

Page 32

Advertising
background image

MasoSine SPS sinusoidal pumps User Manual

32

SPS 200

SPS 250

SPS 300

SPS 400

SPS 500

Cast iron
power frame

Approx 0.10

litre

-

Approx 0.18

litre

Approx 0.38

litre

-

Stainless
steel power
frame

Approx 0.10

litre

Approx 0.10

litre

Approx 0.18

litre

Approx 0.35

litre

Approx 0.45

litre

Dispose of used oil according to local regulations.

Oil or grease needs to be changed at least once a year.

SPS 200, SPS 250, SPS 300, SPS

400, SPS 500

Every day before using your pump, check
the oil viewing glass at B (see 27 in the
parts list, section 25) in the bearing housing (see 11 in the parts list, section 25.1)
for damage and to confirm that enough oil is in the power frame. The oil should
reach the middle of the glass.

l Check that the drain plug C is in place and fully tightened.
l Open port A and fill the power frame with suitable oil (see Note, below) until it

is nearly full.

l Close port A.
l Check the oil level in viewing glass at B. Do not allow the level to fall below the

viewing glass centre line.

Note: If the pump is intended to be used in an area where ATEX regulations apply,
the oil viewing glass is replaced by a screwed plug.

Note: When a new pump is supplied, it is filled as standard with Klüberoil 4 UH
1-220 N lubrication oil for the food and pharmaceutical industries, which is suitable
for process temperatures between –10°C and 60°C. If the pump is intended to be
used in an area where ATEX regulations apply, only this oil must be used.

Filling volumes

19 Oil change

SPS 100

Every day before using your pump, check that there is enough grease in the storage
chamber. Remove the vent at A and insert grease through the nipple at B until
grease starts to come out at A. Refit the vent.

Standard first filling, for -10 to 60°C (14 to 140°F): MOLYDUVAL Soraja C532, DIN
51502.

Grease grades for Ex zones:
l At temperature class T4 (60°C

(140°F) or less: MOLYDUVAL Soraja
C532, DIN 51502.

l At temperature class T3 (61 to 120°C

(142 to 248°F) or less: MOLYDUVAL
Pegasus KD 460.