MasoSine SPS sinusoidal pumps User Manual

72

Pumps with a stainless steel power frame: assembling the pump

housing

l Fit the flush ring. Whichever flush ring is installed, the procedure is the

same. For single mechanical seal system the distance ring is not needed.

l Position the pump housing carefully.
Note: the pump housing is heavy.
l Use a 13mm spanner to fit and tighten the six screws (right-hand

thread) and washers which secure the pump housing to the power
frame.

SPS 200 pumps

with a single

mechanical seal

Note: See page 64 for assembling the pump housing of a pump with a cast iron

power frame.

SPS 200 pumps

with a triple lip

seal

Pumps with a stainless steel power frame and a triple lip seal:

assembling the distance ring

l Fit the distance ring into the flush ring before fitting the flush ring.