Watson-Marlow SPS User Manual

Page 49

Advertising
background image

MasoSine SPS sinusoidal pumps User Manual

49

Pumps with a triple lip seal: fitting the back bushing

l Push the back bushing into position, thick end (arrowed) first. (The two

bushings are identical.)

SPS 100 pumps

with a triple lip

seal

Fitting the rear liner

l Push the rear liner into position, pushing evenly at both ends so that it does

not jam. The anti-rotation pins within the pump housing (arrowed) guarantee
that the liner is properly positioned. The two liners are identical.

Pumps with a triple lip seal: fitting the distance piece

l Check that the distance piece O-ring is in position.
l Push the distance piece into position, flanged end first.

SPS 100 pumps