Watson-Marlow SPS User Manual
Page 49
Advertising
![background image](/files/809045/content/doc049.png)
MasoSine SPS sinusoidal pumps User Manual
49
Pumps with a triple lip seal: fitting the back bushing
l Push the back bushing into position, thick end (arrowed) first. (The two
bushings are identical.)
SPS 100 pumps
with a triple lip
seal
Fitting the rear liner
l Push the rear liner into position, pushing evenly at both ends so that it does
not jam. The anti-rotation pins within the pump housing (arrowed) guarantee
that the liner is properly positioned. The two liners are identical.
Pumps with a triple lip seal: fitting the distance piece
l Check that the distance piece O-ring is in position.
l Push the distance piece into position, flanged end first.
SPS 100 pumps