42
l Note the orientation of the gate and the gate guide so that they can be refitted
in the same orientation. This is important because if the gate guide is refitted
in the wrong orientation the pump will not work properly and the gate guide
can be damaged. Use two hands to remove the rotor, the gate and the gate
guide together.
Removing the rotor, the gate and the gate guide
SPS 100 pumps
The gate and gate guide
shown inverted to make clear
the gate’s position within the
guide for counter- clockwise
rotor rotation