Fault enable – Wavetronix Click 111 (16-channel Contact Closure Eurocard) (CLK-111) - User Guide User Manual

Page 28

Advertising
background image

CliCk 111 • User GUIde

27

the device goes into a fault state it will send a call on the master fault output; this parameter

allows you to choose whether that call is high voltage or low voltage.

Level 1 LEDs

Fault Output Polarity

Level 2 LEDs

High asserted

Low asserted

LED off
LED on

Cancel and exit menu

Table 15 – Front Panel Menu Fault Output Polarity Settings

See the earlier Navigating through the Menu and the Menu Operation Example sections for

how to configure this parameter.

Because this parameter can also be set by the DIP switches, you may need to ensure that the

DIP switches are set to Software configuration mode; if they are set to Hardware, the front

panel menu will be able to display but not change these settings.

Fault Enable

The next parameter on the front panel menu label is fault enable. To select this parameter,

release the push-button when the green and red LEDs come on solid.

Note

This parameter can also be changed using the DIP switches or Click Supervisor.

This parameter lets you choose whether the device will go into a fault state at all. If faults are

disabled, the device will never go into a fault state.

Level 1 LEDs

Fault Enable

Level 2 LEDs

Faults enabled (default)

Faults disabled

LED off
LED on

Cancel and exit menu

Table 16 – Front Panel Menu Fault Enable Settings

See the earlier Navigating through the Menu and the Menu Operation Example sections for

how to configure this parameter.

Advertising