6607-2204

W – Enhance result messages

ATW0

Shows result code (RING, CONNECT) without additional info (default)

ATW1

Shows result code (RING, CONNECT) with address

&W – Store active configuration

The active configuration will be stored in non volatile memory.

AT&W0
AT!&W

!&W – Store active configuration

The active configuration for the analogue option will be stored in non volatile memory.

AT!&W

X – Reduce result messages

Reduces the number of result messages after trying to set up a connection

ATX0“CONNECT” only
ATX1

“CONNECT” with line speed, “BUSY”, “NO DIALTONE” not used

ATX2

“CONNECT” with line speed, “BUSY” not used

ATX3

“CONNECT” with line speed, “NO DIALTONE” not used

ATX4

“CONNECT” with line speed, all messages used (default).

##X – Send an alarm message

Sends the preprogrammed alarm message which is associated with alarm input addressed
with the command parameter.

AT##X1

Send alarm message 1

AT##X2

Send alarm message 2

AT##X3

Send alarm message 3

AT##X4

Send alarm message 4

Z – Load stored settings

The active configuration will be resetted to the stored configuration.
Must be the last command in an AT command line.

ATZ

When the V90 option is present this command will also cause a soft reset
of the V90 modem with a recall of stored configuration profile .

&Z – Store call-number

Stores dialing number nn as entry number x into the telephone list (x = 1..3).

AT&Zx=nn

set entry number x to dialling number nn

AT&Zx

shows entries number x.

AT&Z

show all entries.