recno – Alarm message receiver number

With this command you can set up the receivers number of a alarm message.
There is one entry for each alarm input.

recnox

nn

set entry number x to receiver number nn.

recnox

-

clear entry number x

recnox

show entry number x

recno

show all entries

Maximum number of entries = 4.
Maximum length of receiver number = 20 digits.

Example: recno command (show all entries)

recno1:

01661200

recno2:

049701098505

recno3:

046609734

recno4:

reset – Reset ID-90

Resets the whole functionality of the ID-90 by a forced hardware reset.

ringtimer – Delay of RING messages

Delaytime between two RING messages, if S0 register is set not equal to 1,

value in 100 ms.

Default: ringtimer = 50 (5 sec).

rmmsg – Message for remote access

Display message on the local port, “rmon” for established “rmoff” for disconneced
remote configuration access. If an PAD connection is established the message will be
discarded.

0: display no messages (default)
1: display messages

rmsn – Multiple Subscriber Number for remote

MSN (Multiple Subscriber Number) for remote configuration

*: no specific MSN, all incoming calls accepted

rpwd – Password

Password for remote configuration (character input)

To disable password please enter: rpwd –