Specifications – Westermo ID-90 User Manual

Page 5

Advertising
background image

5

6607-2204

Specifications

Transmission

Interface 1

Asynchronous, full/half duplex or simplex
PPP and ML-PPP Asynchronous & Synchronous
conversion
V110 Asynchronous adaptation up to 19.2 kBit/s

Interface 2

B-channel protocols
V.110 async,V.120 async.
HDLC async. to sync. HDLC transparent
HDLC transparent
Byte transparent
X.75 SLP
X.25 B-Channel
T.70NL and T.90NL
PPP and ML-PPP
D-channel protocols
Euro ISDN DSS1 and French VN4
X.31 Case B D-Channel

Interface 1

RS-232/V.24 9-pin D-sub female. RS-422 and
RS-485 2- and 4-wire with screw terminals

Interface 2

RJ-45

Transmission speed

Interface 1

Up to 115.2 kbit/s

Interface 2

Up to 128 kbit/s

Command interface

Interface 1

AT-command
Configurator remote/local
X3 PAD
Hotline DTR,TxD, Alarm call.

Alarm inputs

Supply
voltage

10–60 V DC 1mA/input @ 10V DC

Power supply

HV-version

95–240 V AC, 110–240V DC ±10%

LV-version

12–45 V AC, 12–55V DC ±10%

Power consumption

HV-version

0.02A, 1.6W
With V90 option 0.05A, 3.5W

LV-version

Max 0.1A, 1.2W
With V90 option 0.25A, 3.0W

Isolation

S0 Interface 1 500 V AC
Alarm

500 V AC

Mains

3 000 V AC

Indicator LED's

TD, RD, DCD, RTS, L1, L2, ANS, ANL

Temperature

5–50°C ambient temperature

Humidity

0–95% without condensation

Dimensions

55x100x128 mm (WxHxD)

Weight

0.4 kg

Mounting

35 mm DIN-rail

Advertising