Westermo ID-90 User Manual

Page 88

Advertising
background image

88

6607-2204

To use Alarm inputs for SMS Call and MINICALL paging.

To set the alarm input 1 to be triggered on a contact breaking condition and transfer
a SMS or MINICALL text message to a receiver GSM telephone or a MINICALL.
For example a house supervision alarm system.

1

2

3

4

5

6

7

8

9

▼▼

▼▼

ATCONF

Set ID-90 in configuration mode

OK
#

Configurator prompt

OPNUMBER1 00491722278000

Number to SMS/MINICALL service provider

#
MESSAGE1 Main Door Opened

Text message to sent

#
MTYPE1 0

0 = SMS/MINICALL (default), 1 = Hotline text

#
RECNO1 0172555555

GSM number that will receive the text message

#
TRANSNO 01721234567

Calling party number

#
MAXRETRIES 4

Number of times ID-90 will retry to send after

#

failed transmission

TRIGCND1 1

0 = No cond.(default) 1 = Break cond. 2 = Make

#

cond.

SAVE

Save above parameters in EEPROM

#

EXIT

Exit from configurator and enter AT-command
mode

Note: It is of importance that you check the physical connection to the alarm inputs

before setting parameter trigcnd to avoid unintentional transmission of alarm

messages.