Screen Line Width

not suppported

11

Local baudrate (Read only)

Displays actual used baudrate on asynchronous line.
1: 1 200 bit/s
2: 2 400 bit/s
3: 4 800 bit/s
4: 9 600 bit/s
5: 19 200 bit/s
6: 38 400 bit/s
7: 57 600 bit/s
8: 115 200 bit/s

12

Local flow control (Read only)

Handles and displays used flow control on asynchronous line.
0: no flow control
3: flow control RTS / CTS
4: flow control XON / XOFF

Extended Parameters 13 through 24

13

Automatic Line Feed
Defines, whether the PAD should automatically append a line feed follow-
ing a carriage return <CR> and – if so – in which case. See parameter 126
also.

Valid Parameter Values:
0

No <LF> added

1

When receiving data from the remote party add a <LF> automatically
after each <CR> received.

2

Add a <LF> automatically after each <CR> received from the local key-
board.

4

By each echo of a <CR> to the screen, also send a <LF>.

Note: This parameter is interpreted bit-wise, thus any combination of the above

listed values can be combined to form a sum of the desired values

14

Line Feed Fill Characters

Defines, whether fill characters <NULL> should be sent following a line
feed <LF> .

Valid Parameter Values:
0

No fill characters <NULL> after a <LF>

n

Following a <LF> on the screen, append n fill characters <NULL>. n is
an integer in the range from 1 to 255.