Verifying the configuration

# Execute the display interface tunnel command on Switch A. The output shows that the tunnel interface

is up.

[SwitchA] display interface tunnel

Tunnel1

Current state: UP

Line protocol state: UP

Description: Tunnel1 Interface

Bandwidth: 64kbps

Maximum Transmit Unit: 64000

Internet Address is 7.1.1.1/24 Primary

Tunnel source unknown, destination 4.4.4.9

Tunnel TTL 255

Tunnel protocol/transport CR_LSP

Last clearing of counters: Never

Last 300 seconds input rate: 0 bytes/sec, 0 bits/sec, 0 packets/sec

Last 300 seconds output rate: 6 bytes/sec, 48 bits/sec, 0 packets/sec

Input: 0 packets, 0 bytes, 0 drops

Output: 177 packets, 11428 bytes, 0 drops

# Execute the display mpls te tunnel-interface command on Switch A. The output shows detailed
information about the MPLS TE tunnel.

[SwitchA] display mpls te tunnel-interface

Tunnel Name : Tunnel 1

Tunnel State : Up (Main CRLSP up, Shared-resource CRLSP down)

Tunnel Attributes :

LSP ID : 23331 Tunnel ID : 1

Admin State : Normal

Ingress LSR ID : 1.1.1.9 Egress LSR ID : 4.4.4.9

Signaling : RSVP-TE Static CRLSP Name : -

Resv Style : SE

Tunnel mode : -

Reverse-LSP name : -

Reverse-LSP LSR ID : - Reverse-LSP Tunnel ID: -

Class Type : CT0 Tunnel Bandwidth : 0 kbps

Reserved Bandwidth : 0 kbps

Setup Priority : 7 Holding Priority : 7

Affinity Attr/Mask : 0/0

Explicit Path : -

Backup Explicit Path : -

Metric Type : TE

Record Route : Disabled Record Label : Disabled

FRR Flag : Disabled Backup Bandwidth Flag: Disabled

Backup Bandwidth Type: - Backup Bandwidth : -

Route Pinning : Disabled

Retry Limit : 10 Retry Interval : 2 sec

Reoptimization : Disabled Reoptimization Freq : -

Backup Type : None Backup LSP ID : -

Auto Bandwidth : Disabled Auto Bandwidth Freq : -