Configuring a cross-connect, Required.) – H3C Technologies H3C S12500-X Series Switches User Manual

Page 258

Advertising
background image

247

To configure a service instance:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter Layer 2 Ethernet

interface view.

interface interface-type
interface-number

N/A

3.

Create a service instance
and enter service instance

view.

service-instance instance-id

By default, no service instance is
created.

4.

Configure match criteria for

the service instance.

Match all incoming packets:

encapsulation default

Match incoming packets with any

VLAN ID or no VLAN ID:

encapsulation { tagged |
untagged }

Match incoming packets with a

specific VLAN ID:
encapsulation s-vid vlan-id

[ only-tagged ]

Use one of the commands.
By default, no match criteria are

configured for the service

instance.

Configuring a cross-connect

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Create a cross-connect group
and enter cross-connect group

view.

xconnect-group group-name

By default, no cross-connect group
is created.

3.

(Optional.) Configure a

description for the
cross-connect group.

description text

By default, no description is
configured for the cross-connect

group.

4.

(Optional.) Enable the
cross-connect group.

undo shutdown

By default, the cross-connect group
is enabled.

5.

Create a cross-connect and
enter cross-connect view.

connection connection-name

By default, no cross-connect is
created.

6.

Configure an MTU for the PW. mtu mtu

The default MTU is 1500 bytes.
The two PEs on an LDP PW must

have the same MTU configured for
the PW. Otherwise, the PW cannot

go up.

Advertising